Products
|
4 DIGIT 19999 COUNTS TRUE RMS DIGITAL MULTIMETER MODEL - 405
| 405 |
 |
Display : |
4 digit LCD display (19999
Counts) |
| Digit Size : |
17mm(H) |
| CE approved
|
IEC - 1010 Overload Category II
|
| DATA HOLD
facility |
|
| Power Consumption
: |
14mW Typical |
| Auto Power
Off : |
Meter automatically shuts down after approx.
45min. of the last reading |
| Polarity : |
Automatic (-) negative polarity
indication |
| Operating
Temperature : |
0C to 50C, < 70% R.H. |
| Storage
Temperature : |
-20C to 60C, < 80% R.H. With
battery removed from meter |
Dimension : 189mm(L) x
87mm(W) x 37mm(H)
Resistance, Diode test & Audible Continuity, Logic Test, Frequency, &
Duty Cycle Function.
Accessories : Test Leads, Carrying Case, User Manual, Battery, Tilt
Stand, Protective Holster |
|
Accuracy : (% reading +digit)
|
|
|
DC VOLTAGE |
|
Range
|
Resolution
|
Accuracy |
|
200 mV |
10 m V |
(0.05% rdg + 3dgts)
|
|
2 V |
100 m V |
|
20 V |
1 mV |
|
200 V |
10 mV |
|
1000 V |
100 mV |
|
|
Input Impedance : 10M

Overload Protection : 500V DC/350V AC rms on 200mV range,
1000V DC/750V AC rms on all other ranges
|
|
|
AC VOLTAGE |
| Range |
Resolution |
Accuracy* |
| 200 mV
|
10 m V
|
(1.0% rdg + 10dgts)
|
| 2 V
|
100 m V
|
|
| 20 V |
1 mV
|
|
| 200 V
|
10 mV
|
|
| 750 V
|
100 mV
|
(2.0% rdg + 20dgts) |
|
Input Impedance : 10M
Overload Protection : 500V DC/AC rms on 200mV
range, 1000V DC/750V AC rms on all other ranges
|
|
|
|
AC VOLTAGE 500Hz to 2 KHz (TRUE RMS)
|
| Range |
Resolution |
Accuracy* |
| 200 mV |
10 m V
|
(2.0% rdg + 20dgts)
|
| 2 VV |
100 m V
|
| 20 V
|
1 mV
|
| 200 V
|
10 mV
|
| 750 V
|
100 mV
|
Unspecified
|
|
Input Impedance : 10M
Overload Protection :
|
|
|
AC VOLTAGE 500Hz to 2 KHz (TRUE RMS) |
| Range |
Resolutionn |
Accuracy* |
|
| 10 nA |
(0.8% rdg + 10dgts)
|
| 2 mA |
100 nA
|
| 20 mA |
1 m A
|
| 200 mA |
10 m A
|
| 20 A |
1 mA
|
(2.5% rdg + 10dgts)
|
|
|
Burden Voltage : 300mV for 200mA, 2mA, 20mA 600mV for
200mA & 800mV for 20A.
Overload Protection : 500mA/600V fuse on mA
inputs (fast blow ceramic fuse). * 20A/600V
fuse on 20A inputs (fast blow ceramic fuse).
|
|
|
|
INDUCTIVE |
| Range |
Resolution |
Accuracy* |
| 2 mH
|
1 m H
|
(5.0% rdg + 20 dgts)
|
| 20 mH
|
10 m H
|
(5.0% rdg + 10 dgts)
|
| 200 mH
|
100 m H
|
| 2 H
|
1 mH
|
| 20 H
|
10 mH
|
|
Test Frequency : 2mH, 20mH ranges 1KHz 200mH, 2H ranges
270Hz, 20H range 27Hz
Test Conditions : quality factor > 5 in 270Hz
|
|
|
AC CURRENT
(True RMS) |
|
Range
|
Resolution
|
Accuracy
|
|
20 mA |
10 m A |
(1.5% rdg + 4 dgts)
|
|
200 mA |
100 m A |
|
|
10 mA |
(3.5% rdg + 4 dgts)
|
|
|
Input Protection :
|
|
|
|
DC CURRENTT |
| Range |
Resolution |
Accuracy* |
|
| 10 nA
|
(0.5% rdg + 5dgts) |
| 2 mA
|
100 nA
|
| 20 mA
|
1 m A
|
| 200 mA
|
10 m A
|
| 20 A*
|
1 mA |
(2.0% rdg + 10dgts)
|
|
Burden Voltage : 300mV for 200mA, 2mA, 20mA 600mV for
200mA & 800mV for 20A.
Overload Protection :
|
|
|
FREQUENCY
(Auto Ranging ) |
|
Range
|
Resolution
|
Accuracy |
Input
Impedance |
|
2 KHz |
0.1 Hz |
|
|
|
20 KHz |
1 Hz |
| 10M W // 10 pF
|
|
200 KHz |
10 Hz |
|
|
|
|
Sensitivity : 50mV rms (Sine Wave), 400mV rms at > 30%
and < 70% duty cycle
Input Frequency : More than 10 Hz at pulse width
> 2 m sec. Overload Protection :
500V DC or AC rms
|
|
|
|
RESISTANCEE |
|
Range |
Resolution |
Basic
DC Current |
| 200 W
|
0.01 W
|
|
| 2 K W
|
0.1 W
|
(0.15% rdg + 3dgts)
|
| 20 K W
|
1 W
|
| 200 K W
|
10 W
|
| 2 M W
|
100 W
|
(0.25% rdg + 10dgts)
|
| 20 M WW |
1 K W
|
|
|
Overload Protection : 500V DC or AC rms
Burden Voltage : 3.3V DC |
|
|
LOGIC TEST |
|
Threshold
|
Pulse Width (min)
|
|
Pulse Rise(max)
|
|
Logic
Hi ( ) |
Logic Low ( ‚ )
|
25nsec |
1Mpps |
10 m sec |
|
2.8V 0.8V |
0.8V 0.5V |
|
200
KHz |
10 Hz |
|
|
|
|
Test Voltage : 5V DC Impedance : 120K W // 100pF
Duty Cycle : >20% and <80%
Indication : 40msec beep at logic Hi
500V DC or AC rms
Frequency Response ::
|
|
|
|
CONTINUITY TESTT |
| Range |
Audible
Indication |
Response Time |
Open
Circuit Volts |
| 2 V |
Less than 150 W
|
Approx. 500ms
|
3.3V DC Typical
|
|
Overload Protection : 500V DC or AC rms
|
|
|
DUTY CYCLE |
| Range |
Audible
Indication |
Response Time |
Open
Circuit Volts |
| 0 - 90.0%
|
0.1 %
|
> 10 m sec.
|
(2.0% rdg + 10 dgts)
|
|
Overload Protection : 500V DC or AC rms
Frequency Range :
|
|
|
|
DIODE TESTT |
| Range |
Resolution |
Accuracy |
Test
Current |
Open
Circuit Volts |
| 2 V |
0.1mV |
(0.5% rdg + 1dgts)
|
3.3V DC Typical
|
|
Overload Protection : 500V DC or AC rms |
|
|
|
|
|
|
|