=====================================================================  Products
 
DUAL TRACE OSCILLOSOCPE
KM - 20 - 10 - 20MHz Oscilloscope
KM – 20 – 20 – 20MHz Oscilloscope With Frequency Counter

Description
These 20MHz Oscilloscope are dual- channel oscilloscope with maximum sensitivity of 1 mV/DIV. The time base provides a maximum sweep time of 0.2 µ S/DIV. When magnified by 10, the sweep speed is 20nS/DIV. These oscilloscope employ a 6-inch rectangular type TOSHIBA cathode-ray tube with red internal graticule. These oscilloscopes are sturdy, easy to operate and exhibit high operational reliability.

Special Features :
• High luminance, internal graticule Toshiba CRT
• Japanese electronic encoder, light handy and reliable
• Fully sealed long live vertical mode switch
• ALT Triggering Function. Two independent signals simultaneous observation.
• Triggering Level Lock Function, Automatic Synchronize Function.
• Built-in 6 Digit Frequency Counter. (*available in model KM – 20-20)
• High intensity CRT with high acceleration voltage : The CRT is a high beam transmission, high intensity type
  with a high acceleration voltage of 2KV. It displays clear readable traces even at high sweep speeds.
• The Oscilloscope has a trigger level lock function which makes the triggering adjustment unnecessary.
• Alternate triggering : Even an observation of two waveforms of different frequencies, the waveform of the each channel
  is stably triggered.
• TV sync triggering : The oscilloscope has a sync separator circuit for triggering of TV-V and TV-H signals.
• CHI Output : Terminated 50 output of channel 1 signal available on rear panel for driving frequency counter or
  other instruments.
• Z-Axis Input : Intensity modulation capability permits time or frequency markers to be added. Trace blank with
  positive signal, TTL compatible.
• X-Y operation : Set the switch to X-Y. Then the instrument works as an X-Y oscilloscope. CH1 can be applied as
  horizontal deflection (X-axis) while CH2 provide vertical deflection (Y-axis).
 

Input Power : AC/110/220V ±10%
Power Consumption : Approx. 40 VA
Weight : Approx. 8kg.
Frequency : 50/60 Hz
Dimension : 310(W) x 150(H) x455(D)mm
 
VERTICAL AXIS

Sensitivity

5mV ~ 20V/DIV

Vernier vertical Sensitivity

To 1/2.5 or less of panel – indicated value

Sensitivity Accuracy

< 3% (x5 MAG : < 5%)

Frequency bandwidth

DC ~ 20MHz (x5 MAG:DC ~ 7MHz)
AC coupling: Low limit frequency 10Hz. (with reference to 100KHz, 8DIV. Frequency response with- 3dB)

Rise time

Approx. 17.5nS (x5MAG:Approx. 50nS)

Input impedance

Approx. 1M // Approx. 25pF

Square wave characteristics

Overshoot: < 5% (At 10mV/DIV range)
Other distortions and other ranges : 5% added to the above value.

DC balance shift

Adjustable on panel.

Linearity

< ±0.1 DIV of amplitude change when waveform of 2 DIV at graticule center is moved vertically.

Vertical Mode

CH1 : CH1 single channel.
CH2 : CH2 single channel.
DUAL : CH1 and CH2 are Displayed. ALT or CHOP selectable at any sweep rate.
ADD : CH1 + CH2 algebric addition.

Chopping repetition frequency

Approx. 250 KHz

Input coupling

AC , GND , DC

Maximum input voltage

300V peak (AC : frequency 1 KHz or lower)
When set probe switch at 1:1, the maximum effective readout is 40Vpp (14Vrms at sine wave ), or set probe switch at 10:1 , the maximum effective readout is 400Vpp(140Vrms at sine wave).

Common mode rejection ratio

50:1 or better at 50KHz sinusoidal wave. (When sensitivities of CH1 and CH2 are set equally)

Isolation between channels (At 5mV/DIV range)

>1000:1 at 50KHz
>30:1 at 20KHz

CH1 signal output

At least 20mV/DIV into a 50 ohm termination. Bandwidth is 50Hz to at least 5MHz.

CH2 INV BAL.

Balanced point variation : < 1 DIV (Reference at center graticule.)


 
TRIGGERING
Triggering source
CH1, CH2, LINE, EXT(CH1 and CH2 can be selected only when the vertical mode is DUAL or ADD.) In ALT mode, if the TRIG. ALT switch is pushed in, it can be used for alternate triggering of two different source.
Coupling
AC : 20 Hz to full bandwidth
Slope
+ / -
Sensitivity
20 Hz ~ 2 MHz : 0.5 DIV, TRIG - ALT : 2 DIV, EXT : 200 mV 2 ~ 20 MHz : 1.5 DIV TRIG - ALT : 3 DIV, EXT : 800 mV TV : Sync pulse more than 1 div ( EXT : 1V )
Triggering modes
AUTO: Sweeps run in the free mode when no triggering input signal is applied. (Applicable for repetitive signals of frequency 25Hz or over.) 
NORM: When no triggering signal is applied, the trace is in the ready state and not displayed. 
TV-V : This setting is used when observing the entire vertical picture of television signal 
TV-H : This setting is used when observing the entire horizontal picture of television signal. (Both TV-V and TV-H synchronize only when the synchronizing signal is negative)
EXT triggering signal input Input impedance Max. input voltage
Approx. : 1M ohm // approx.25pF 300V (DC + AC peak), AC: Frequency not higher than 1KHz

 
HORIZONTAL AXIS

Sweep time

0.2 µ Sec ~ 0.5 Sec / DIV, 20 steps in 1-2-5 sequence

Sweep time accuracy

+/-3%

Vernier sweep time control

< 1/2.5 of panel-indicated value

Sweep magnification

10 times

x10MAG sweep time accuracy

+/-5% (20nSec~50nSec are un calibrated)
+/-3%, x10MAG: +/-5% (20ns and 50ns are un calibrated)

Position shilft caused by x 10MAG

Within 2 DIV. At CRT screen center


 
X – Y MODE
Sensitivity Same as vertical axis. (X-axis: CH1 input signal; Y-axis:CH2 input signal)
Frequency bandwidth DC to at least 500KHz
X-Y phase difference 3Deg at DC ~ 50KHz

 
Z – AXIS
Sensitivity 20Vp-p (Positive-going signal decreases intensity)
Frequency bandwidth DC ~ 2 MHz
Input resistance Approx. 47K
Max. input voltage < 30V (DC+AC peak, AC frequency 1KHz)

 
CALIBRATION VOLTAGE

Waveform

Positive-going square wave

Frequency

Approx. 1 KHz

Duty ratio

Within 48:52

Output voltage

2Vp-p +/-2%

Output impedance

Approx. 1 K ohm


 
CRT

Type

6-inch rectangular type, internal graticule

Phosphor

P31

Acceleration voltage

Approx. 2KV

Effective screen size

8 x 10 DIV (1 DIV=10mm(0.39in)

Graticule

Internal

Trace rotation

Provided

 

Designed & Hosted by : MID    Promoted by : GID