====================================================================  Products

3½ DIGIT LARGE DISPLAY DIGITAL MULTIMETER MODEL : 6030

Low power consumption CMOS double integration, A/D transform integrated circuit, Auto Zero Calibration, Auto Polarity display, Data Hold, Low Battery & Over range indication.
Display : 3½ digit (1999 Counts) with digit height 28mm and function/units sign annunciators
Test lead jack mechanical protection function & full Range over-load protection function.
Auto Power Off : The meter will shut off automatically about 15 Minutes after the last function performed.
Operating Temperature: 0°C to 40°C, < 85%
Storage Temperature : -10°C to 50°C, < 85%
Power : One standard 9V battery
Low Battery Indication : will occur on the left top of the LCD.
Dimension : 192mm(L) x 88mm(W) x 42mm(H)
Weight : Approx. 600g. (Including battery and holster).
Safety : CE mark certified
Accessories : Test Leads, Temperature Probe, Holster, User Manual, Carrying Case, Battery, Tilt Stand.
Accuracy : ±(% reading +digit)
 DC VOLTAGE
 Range  Resolution  Accuracy*
 200 mV  100 m V
 ± (0.5% rdg + 3 dgts)
 2 V  1 mV
 20 V  10 mV
 200 V  100 mV
 1000 V  1 V  ± (0.8% rdg+ 3 dgts)

Input Impedance :
10M
Overload Protection : 250V (for 200mV), DC or AC peak value 1000 V (for other range)
 AC VOLTAGE
 Range  Resolution  Accuracy*
 2 V  1 mV
 ± (0.8% rdg + 3 dgts)
 20 V  10 mV
 200 V  100 mV
 700 V  1 V  ± (1.2% rdg + 5 dgts)

Input Impedance :
2M Others are 10M
Frequency range : 40Hz-400Hz (it is 40Hz-100Hz in 200V,750V range position).
Overload Protection : 250V (for 200mV), DC or AC peak value 1000 V (for other ranges)
Display : Average value (Sine RMS)
 AC CURRENT
 Range  Resolution  Accuracy*
 2 mA  1 m A  ± (1.0% rdg + 3dgts)
 20 mA  10 m A
 200 A  100 m A  ± (1.8% rdg  + 3dgts)
 20 A  10 mA  ± (3.0% rdg  + 7dgts)
 DC CURRENT
 Range  Resolution  Accuracy*
 2 mA  1 m A  ± (0.8% rdg + 2dgts)
 20 mA  10 m A
 200 mA  100 m A  ± (1.2%rdg + 2dgts)
 20 A  10 mA  ± (2% rdg+ 5dgts)

Overload Protection :
0.2A/250 V Fuse
Voltage drop measurement : Full-range
Voltage drop : 200mV
Frequency range : 40Hz-400Hz
Display : Average value (Sine Wave)
 

Overload Protection :
0.2A/250 V Fuse
Voltage drop measurement : Full-range
Voltage drop : 200mV
 CAPACITANCE
 Range  Resolution  Accuracy*
 2 nF  1 pF  ± (0.8% rdg+ 3dgts)
 20 nF  10 pF  ± (3.0% rdg+ 3dgts)
 200 nF  100 pF
 2 m F  1 nF
 200 m F  100 nF  ± (5.0% rdg+ 3dgts)

Frequency measurement : Approx. 400 Hz
Voltage measurement :
Approx. 40 mV.


 

 RESISTANCE
 Range  Resolution  Accuracy*
 200  0.1 ± (0.8% rdg+ 3dgts)
 2 K  1 ± (0.8% rdg + 2dgts)
 20 K  10
 200 K  100
 2 M  1 K
 20 M  10 K ± (1.0% rdg + 5dgts)

Overload Protection :
250 V DC or AC peak value.
Open circuit voltage : < 1 V

 
 TRANSISTOR hFE PARAMETER MEASUREMENT
 Range  Description
  hFE
 It can measure NPN or PNP  type of transistor triode hFE  parameter. Indication range :  0~1000
 1b approx. 10 m A, Vec  approx. 2.8V
  FREQUENCY
 Range  Resolution  Accuracy*
 2 KHz  1 Hz  ± (2.0% rdg+ 5dgts)

Overload Protection :
500 V DC or AC peak value.
Input Sensitivity : 150 mV rms


 
 DIODE AND CONTINUITY MEASUREMENT
 Description
 Indicate approx forward-way  voltage drop of diode
 Forward-way current is approx. 1mA  contray- way voltage is approx. 2.8V. Open  circuit voltage is approx.2.8V.
 The buzzer inside sounds  when  continuity resistance is  about <50
  TEMPERATURE TEMPERATURE TEMPERATURE TEMPERATURE
 Range  Resolution  Accuracy*
 -40 o C~400 o C  1 o C  +(0.75% rdg +4dgts)
 400 o C~1000 o C  +(1.5% rdg +15dgts)

 

  Designed & Hosted by : MID   Promoted by : GID