==================================================================  Products
 
3 5/6 DIGIT 5000 COUNTS PROFESSIONAL GRADE DIGITAL MULTIMETER
WITH ANALOG BAR GRAPH & RS-232 COMPUTER INTERFACE MODEL - 5040

 
Special Features
Display : 3-5/6 digit LCD display (5000 Counts)
Professional Grade Digital MultiMeter with optically Isolated RS 232C PC interface capability.
Data Hold facility  
Back lighted large LCD Display.
EN61010-1 approval. Cat II. 1KV AC/DC & Cat III 600V AC/DC.
Fire retarded case with Splash Proof construction & protective Holster.
Fast measurement 5 Times/Sec. 600V Input protection.
Sensing : Average sensing.
Operating Temperature : 0°C to 40°C, 0-80% R.H.
Storage Temperature : -20°C to 60°C, 0-80% R.H.(With Battery Removed )
Power Consumption : 2.6mA Typical.
 
Dimension :
186mm(L) x 87mm(W) x 35.5mm(H)
Accessories :
Test Leads, Holster, Carrying Case, user Manual, Battery. PC interface kit (RS 232 optical adapter cable + RS232 Software floppies), Tilt stand.
Digit Size :
18mm(H)
Fully Auto-Ranging
Auto Power Off.
Analog 52 segment BAR GRAPH Display
Low Battery :
Below approx. 7V.
Transient protection upto 6.5KV (1.2/50 m S Light Surge).
Auto Power Off timing :
Idle for 17 minutes
Weight :
Approx. 430g. With holster.
Accuracy : ±(% reading +digit)
 DC VOLTAGE

 Range

 Accuracy

 Resolution

 50 mV

 ± (0.12% rdg + 2 dgts)

 10 m V
 500 mV

 ± (0.06% rdg + 2 dgts)

 100 m V
 5 V  ± (0.08% rdg + 2 dgts)  1 mV
 50 V  10 mV
 500 V  100 mV
 1000 V  1 V

NMRR : >60dB @ 50/60Hz
CMRR :
>120dB @ DC. 50/60Hz, Rs =1k
Input Impedance :
10M , 16pF nominal
(44pF nominal for 50mV & 500mV ranges)


 
 AC CURRENT

 Range

 Resolution

 Accuracy

 (50Hz – 60Hz)

 500 m A

 100 nA

 ± (0.6% rdg + 3 dgts)

 5000 m A

 1 m A

 50 mA

 10 m A

 500 mA

 100 m A

 ± (1.0% rdg + 3 dgts)

 5 A

 1 mA

 ± (0.6% rdg + 3 dgts)

 10 A*

 10 mA

 (40Hz – 1kHz)

 500 m A

 100 nA

 ± (0.8% rdg + 4 dgts)

 5000 m A  

 1 m A

 50 mA

 10 m A

 500 mA

 100 m A

 ± (1.0% rdg + 4 dgts)

 5 A

 1 mA

 ± (0.8% rdg + 4 dgts)

 10 A*

 10 mA

Burden Voltage : 0.15mV/ m A for 500 m A, 5000 m A
3.3mV/mA for 50mA, 500mA & 0.03V/A for 5A,10A.
* 10A continuous, 20A for 30 seconds max with 5
minutes cool down interval.

 DC CURRENT

 Range

 Accuracy

 Resolution

 500 m A

 ± (0.2% rdg + 4 dgts)

 100 nA

 5000 m A

 1 m A

 50 mA

 10 m A

 500 mA

 100 m A

 5 A

 1 mA

 10 A*

 10 mA

Burden Voltage : 0.15mV/ m A for 500 m A, 5000 m A
3.3mV/mA for 50mA, 500mA & 0.03V/A for 5A,10A. * 10A continuous, 20A for 30 seconds max with 5 minutes cool down interval.

 RESISTANCE

 Range

Accuracy

Resolution

 50

 ± (0.2% rdg + 6 dgts)

 0.01  

 500  

 ± (0.1% rdg + 3 dgts)

 0.1

 5 K
 ± (0.1% rdg + 2 dgts)
 1

 50 K

 10

 500 K

 100

 5 M

 ± (0.4% rdg + 3 dgts)

 1 K

 50 M

 ± (1.5% rdg + 5 dgts)

 10 K

Open Circuit Voltage : <1.3V DC (<3V DC for 50 & 500                                anges).

 AC VOLTAGE

 Range

  Resolution 

 Accuracy
 (50Hz – 60Hz)
 50 mV  10 m V    ± (0.5%rdg + 3 dgts
 500 mV  100 m V
 5 V    1 mV
 50 V    10 mV
 500 V  100 mV
 1000 V  1 V
 (40Hz – 500Hz)
 50 mV  10 m V  ± (0.8% rdg + 3 dgts)
 500 mV  100 m V
 5 V    1 mV  ± (1.0% rdg + 4 dgts)
 50 V  10 mV
 500 V  100 mV
 1000 V  1 V  ± (1.2% rdg + 4 dgts)
 (Upto 20KHz)
 50 mV  10 m V  0.5 db*
 500 mV  100 m V
 5 V  1 mV  3 db*
 50 V    10 mV
 500 V  100 mV
 1000 V  1 V  Unspecified

*Specified from 30% to 100% of range
CMRR :
>60dB @ DC to 60Hz, Rs =1k
Input Impedance : 10M , 16pF nominal
(44pF nominal for 50mV & 500mV ranges)

 CAPACITANCE

Range

Accuracy

Resolution

 50 nF

 ±(0.8%rdg + 3 dgts)

 10 pF
 500 nF  100 nF
 5 m F

 ±(1.0%rdg + 3 dgts)

 1 nF
 50 m F

 ±(2.0%rdg + 3 dgts)

 10 nF
 500 m F

 ±(3.5%rdg + 5 dgts)

 100 nF
 9999 m F

 ±(5.0%rdg + 5 dgts)

 1 m F

* Accuracies with film capacitor or better.

 
FREQUENCY

 Function

 Sensitivity (Sine RMS)

 Range
 mV  300 mV  5Hz – 125 kHz
 5 V    2 V
 50 V  20 V  5Hz – 20 kHz
 500 V  80 V  5Hz – 1 kHz
 1000 V  300 V
 W , cx, Diode m A, mA, A  300 mV 10% F.S.  5Hz – 125 kHz

Accuracy : 0.01% rdg + 2 dgts.

 
DIODE TEST
 Range  Accuracy  Test Current  Open Circuit Volt
 2.000 V  ± (1.0% rdg + 1 dgt)  0.8mA  <3.5V DC

 
AUDIBLE CONTINUITY TESTER

 Audible threshold

 Between 20 and 120  

 Response time

 <100 m s

 

 

Designed & Hosted by : MID   Promoted by : GID