========================================================================  Products
 
NEW 5 4/5 Digits Hand Held DIGITAL MULTIMETER 50000/500,000 counts

Features :
Record MAX, MIN, MAX-MIN reading. Crest (Instantaneous Peak hold) MAX, MIN, MAX- MIN reading. Relative zero mode. 500,000 counts high resolution stable reading mode.
Backlighted display, dBm readings.T1-T2 differential temperature readings (KM859CF only).  %4-20mA loop current readings. High noise rejection filtered Line Level Frequency mode. Data Hold. Audible & Visible input warning.

DISPLAY : 4-4/5 digits 50,000 counts. Selectable stable mode 5-4/5 digits 500,000 counts for DC Voltage, & 6 digits 999,999 counts for frequency.
POLARITY : Automatic
UPDATE RATE : 4-4/5digits fast mode : 5 per second nominal; 5-4/5 digits stable mode : 1.25 per second nominal; 42 Segments Bar Graph : 60 per second max
Low battery indication
Data hold Function
LOW BATTERY : Below approx. 7V
OPERATING TEMPERATURE : 0°C to 45°C, £ 80% R.H.
STORAGE TEMPERATURE : -20°C to 60°C, 80% R.H. (With battery removed)
SENSING : AC, AC+DC True RMS
POWER SUPPLY : Single alkaline 9V battery.
POWER CONSUMPTION : 5 mA typical
APO TIMING : Idle for 4.5 minutes
APO CONSUMPTION : 20 m A
DIMENSION : (L) 186mm X (W) 87mm X (H) 35.5mm; (L) 198mm X (W) 97mm X (H) 55mm with holster
WEIGHT : 390 gm; 500 gm with holster Approx.
SAFETY : The Meters meet the requirements for double insulation to IEC61010-1 (1995), EN61010-1 (1995), UL3111-1(6.1994), CSA C22.2 NO. 1010-1-92 Installation CategoryIII 1000 Volts ac and dc,CAT IV 600V DC & AC.
E.M.C. : Meets EN55022(1994/A1; 1995/Class B) and EN50082-1(1992).
 

OVERLOAD PROTECTION

ACCURACY:
m A & mA :
0.63A/500V, IR 100kA, F fuse for KM857;1A/600V, IR 100kA, F fuse for KM859CF
A : 12.5A500V, IR 10kA, F fuse for KM857;15A/1kV, IR 10kA F fuse for KM859CF
V : 1050Vrms, 1450Vpeak; mV : W & Others : 600VDC/AC rms for KM857 (1050Vrms, 1450Vpeak for KM859CF

TRANSIENT PROTECTION : 8kV (1.2/50 m s surge)

STANDARD ACCESSORIES : Test leads (pair), holster, battery installed, user's manual, banana plug K type Thermocouple x1(KM859CF only), Tilt stand.

OPTIONAL ACCESSORIES : PC interface Kit (RS232 optical adapter cable + RS232 Software floppies)

ELECTRICAL SPECIFICATION

ACCURACY:
± (%Reading + number of digits) or otherwise specified, at 23°C ± 5°C & less than 75% relative humidity. True RMS voltage & current accuracies are specified from 5 % to 100% of range or otherwise specified, Maximum Crest Factor < 5:1 at full scale & <10:1 at half scale, and with frequency component within the specified frequency bandwidth for non-sinusoidal waveforms.

 

DC VOLTAGE
   Range
Accuracy
 
 KM859CF
  KM857
 
Accuracy

 500.00mV, 5.0000V,
 50.000V

 0.02%rdg+2dgts  0.03%rdg +  2dgts
 500.00V  0.04%rdg+2dgts  0.05%rdg+2dgts
 1000.0V  0.05%rdg+2dgts  0.1%rdg+2dgts

NMRR :
> 60dB @ 50/60Hz
CMRR : > 120dB @ DC, 50/60Hz, Rs = 1k
Input Impedance : 10M W , 30pF nominal (80pF nominal for 500mV ranges)

 

CAPACITANCE
 Range  Accuracy*
 50.000 nF  0.8%+ 3d
 50.000 nF  0.8%+ 3d
 50.000 nF  1.0%+ 3d
 50.000 nF  2.0%+ 3d
 50.000 nF  3.5%+ 5d
 9999 m F  5.0% + 5d

*Accuracies with film capacitor or better


 

 

DIODE TESTER
 Range  Accuracy  Test Current  (Typical )  Open Circuit  Voltages

 5.0000V

 1%+ 1d
 0.8mA
 <3.5 VDC


dBm :
At 600 , -11.76dBm to 54.25dBm,
Accuracy : ± 0.25dB + 2d (@40Hz -- 20kHz)
Input Impedance : 10M W , 30pF nominal Selectable reference impedance values of 4, 8, 16, 32, 50, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 600, 800, 900, 1000, 1200
Crest mode (Instantaneous Peak Hold) :
Accuracy :
Specified accuracy ± 100 digits for changes > 0.8ms in duration

~ Hz Line Level Frequency
 Range  Accuracy*
 50.000 nF  0.8%+ 3d
 50.000 nF  0.8%+ 3d
Sensitivities (Sine RMS):
0.1V min @500mV range
T 1V min @5V range
10V min @50V range
100V min @500V range
900V min @1000V range


 

 


 
AC & AC + DC CURRENT
 Range
 KM859CF
 KM857

 Burden Voltage

 
Accuracy
 50Hz - 60Hz
0.5% + 50d
1.0% + 40d
 0.15 mV/ m A
 500.00 m A
 0.15 mV/ m A
 5000.0 m A
 3.3 mV/mA
 500.00 mA
 3.3 mV/mA
 5.0000 A
 0.03 V/A
 10.000 A*
 0.03 V/A
 40Hz - 1kHz
     
 500.00 m A
0.7% + 50d
 
 
 
1.0% + 40d
 
 
 0.15 mV/ m A
 5000.0 m A
 0.15 mV/ m A
 50.000 mA
 3.3 mV/mA
 500.00 mA
 3.3 mV/mA
 5.0000 A
 0.03 V/A
 10.000 A*
 0.03 V/A
1kHz - 10kHz
     
 500.00 m A      0.15 mV/ m A
 5000.0 m A      0.15 mV/ m A
 50.000 mA      3.3 mV/mA
 500.00 mA
2.0% + 50d
Unspec'd
 3.3 mV/mA
 5.0000 A  10.000 A*
Unspec'd
Unspec'd
 0.03 V/A


*10A continuous, 20A for 30 second max with 5 minutes cool down interval


 
OHMS
 Range  KM859CF  KM857
 
Accuracy

 500.00

 0.07% + 10d
0.1% + 6d
 5.0000 k
0.07% +2d
 50.000 k
 500.00 k
 5.0000 M  0.2% + 6d  0.4% + 6d
 50.000 M  2.0% +6d  2.0% + 6d
     


Open Circuit Voltage :
< 1.3 VDC (<3VDC for 500 W ranges)


 
Hz LOGIC LEVEL FREQUENCY
 Range  Accuracy

 5.0000Hz- 2.00000MHz

 0.002%+4d

Sensitivities : 2.5Vp square wave


 
% DUTY CYCLE
 Range  Accuracy

 0.1% -- 99.99%

 3d/kHz + 2d


Input Frequency :
5Hz - 500 kHz, 5V Logic family

 


 
T1-T2 DUAL TEMPERATURE (KM859CF only)
 Range Accuracy
 -50.0 °C TO 1000.0°C  0.3% + 1°C

 -58.0 °F TO 1832.0°F

 0.3% + 2°F


Thermocouple range & accuracy not included


 
% DUTY CYCLE
Range Accuracy

 0.1% -- 99.99%

 3d/kHz + 2d


Input Frequency :
5Hz - 500 kHz, 5V Logic family


 
DC CURRENT
Range Accuracy Burden Voltage
 500.00 m A  0.15% rdg + 20dgts  0.15 mV/ m A
 5000.0 m A  0.1% rdg + 20dgts  0.15 mV/ m A
 50.000 mA  0.15% rdg + 10dgts  3.3 mV/mA
 500.00 mA  0.1% rdg + 20dgts  3.3 mV/mA
 5.0000 A  0.5% rdg + 10dgts 0.03 V/A
 10.000 A*  0.5% rdg + 20dgts 0.03 V/A


*10A continuous, 20A for 30 second max with 5 minutes cool down interval
DC Loop Current %4--20mA
4mA = 0% (zero); 20mA = 100% (span)
Resolution : 0.01% Accuracy : ± 25d
))) Audible Continuty Tester
Audible threshold : between 20 W and 120 W . Response time
< 100 m s

 


 

 


 
AC & AC + DC VOLTAGE
Range
KM859CF
KM857
 
Accuracy
 20Hz - 45Hz
   
 500.00mV,  5.0000V, 50.000V
 1.5%rdg+40dgts  Unspec'd
 500.00V, 1000.0V
 Unspec'd
45 Hz - 300 Hz
 500.00mV
 0.3%rdg+20dgts  0.8%rdg+60dgts
 5.0000V, 50.000V
 0.8%rdg+20dgts
 500.00V, 1000.0V
 0.4%rdg+40dgts
 
300Hz - 5kHz
300Hz - 1kHz
 500.00mV,
 0.3%rdg+10dgts  0.8%rdg+40dgts
 5.0000V, 50.000V  500.00V
 0.4%rdg+40dgts  2.0%rdg+60dgts
 1000.0V
 0.8%rdg+40dgts  (300Hz--1kHz)  1.0%rdg+40dgts
 
5kHz - 20kHz
1kHz - 20kHz
 500.00mV,  0.5%rdg+20dgts  1dB* *
 5.0000V, 50.000V  0.8%rdg+20dgts  2dB* *
 500.00V  0.5%rdg+20dgts  3dB* *
 1000.0V  Unspec'd  Unspec'd
 
20kHz -- 100kHz
 
 500.00mV,  2.0%rdg+40dgts  Unspec'd
 5.0000V, 50.000V  4.0%rdg+40dgts* *
 500.00V  Unspec'd
 1000.0V


* From 5% to 10% of range : accuracy % of reading (or in dB) + 80d
** From 5% to 10% of range : accuracy % of reading (or in dB) + 180d
** From 10% to 15% of range : accuracy % of reading
(or in dB) + 100d
CMRR :
> 90dB @ DC to 60Hz, Rs = 1k
Input Impedance :
10M , 30pF nominal (80pF nominal for 500mV range)
Residual reading less than 50 digits with test leads shorted.


 

 
 Designed & Hosted by : MID   Promoted by : GID