AC CURRENT |
Range
|
Resolution
|
Accuracy
|
| 0 to 999.9A
|
0.1 A
|
±(2.0%rdg +5dgts) on 10-100Hz
|
| ±(6.0%rdg +5dgts) on 100Hz-400Hz
|
Overload Protection : 1000A AC max.
for 1 min.
|
AC VOLTS(10
–400 Hz) |
| Range
|
Resolution
|
Accuracy
|
| 0 to 600.0 (600V)
|
0.1 V
|
±(1.0%rdg +5dgts) on 10-100Hz
|
| ±(6.0%rdg +5dgts) on 100- 400Hz
|
Input Impedance :1M

Overload Protection : 600V DC or AC rms.
|
CAPACITANCE
|
| Range
|
Resolution
|
Accuracy
|
| 0 to 999.9 µ F
|
0.1 µ F
|
± (5.0%rdg + 10dgts)
|
Overload Protection :
600V DC or AC rms.
|
TEMPERATURE
(K-Type Thermocouple ) |
| Range
|
Resolution
|
Accuracy
|
| -40 o C to 1200 o C
|
0.1 o C on -40 o C to 999.9 oC
|
± (0.5% rdg + 1 o C)
|
| 1 o C on 1000 o C to 1200 o C
|
| 40 o F to 2200 o F
|
0.1 o F on -40 o F to 999.9 oF |
± (0.5% rdg + 2 o F), (not including
thermocouple error) |
| 1 o F on 1000 o F to 2200 o F
|
Overload Protection :
600V DC or AC rms. |
| DC CURRENT
(ACCURACY : at the center of CT) |
| Range
|
Resolution
|
Accuracy
|
| 0 to 999.9A
|
0.1 A
|
(± 2%rdg + 5dgt)
|
Overload protection : 1200 A D C Max.
for 1 Min.
|
RESISTANCE (Autorange) |
| Range
|
Resolution
|
Accuracy
|
|
0 to 999.9
 |
0.1
|
± (1.5%rdg + 5dgt)
|
|
1000 to 9999
|
1
|
Overload Protection :
600V DC or AC rms.
|
FREQUENCY
|
| Range
|
Resolution
|
Accuracy
|
| 10 to 400.0Hz
|
0.1 Hz
|
± (0.5%rdg + 5dgts
|
Sensitivity : 5Vrms
TTL signal, = 5A @10 to 100Hz,
10A @100 to 400Hz
Overload Protection : 600V DC or AC rms.
|
CONTINUITY |
Audible indication less
than 30
|
Overload Protection :
600V DC or AC rms.
|
DIODE TEST
|
Accuracy :
± (3.0% rdg + 3dgts)
Resolution : 1mV
Test current : 0.2mA
Test Voltage : <2.8V |
|