400A Dc/Ac Autoranging True RMS Clamp-On Meter With Full Multimeter Ranges

400A Dc/Ac Autoranging True RMS Clamp-On Meter

Model KM 061 -AVERAGE SENSING - 18 FUNCTION 37 RANGES
Model KM 062 - TRUE RMS SENSING - 20 FUNCTION 37 RANGES

Special Features
• Measure line-level ACV frequency via test leads
• Relative Zero feature
• 4000 Counts high resolution, Fast measurements
• Versatile & Handy
• Backlight display (KM 062)
• Fully Autoranging on all functions for ease of use
• AC True RMS Voltage & Current Functions (KM 062)
• 30ms Max HOLD to capture in-rush currents
• DCA / ACA 0.1A to 400A non-invasive current measurements.
• Display Hold, PEAK-rms MAX HOLD & Data Hold
• Fast Audible Continuity
• Diode Test

General Specifications
Sensing : Average Sensing (KM 061) ; True RMS sensing (KM 062)
Jaw opening & Conductor diameter : 30mm max
Display : 3-3/4 digits 4000 counts LCD display
Update Rate : 3 per second nominal
Polarity : Automatic
Low Battery : Below approx 2.4V
Operating Temperature : 0 °C to 40 °C
Relative Humidity : Maximum relative humidity 80% for temperature upto 31 °C
  decreasing linearly to 50% Relative Humidity at 40 °C
Altitude : Operating below 2000m
Storage Temperature : -20 °C to 60 °C, < 80% R.H. (With battery removed)
Temperature Coefficient : nominal 0.15 x (specified accuracy) /
  °C @ (0 C-18 °C or 28 C-40 °C), or otherwise specified
Power supply : Standard 1.5V AAA Battery x 2.
Power Consumption :
  DCA & ACA : 11mA typical
  Other function : 2.9mA typical
APO Timing : Idle for 30 minutes
APO Consumption : 190 µA typical
Dimension : 188(L) x 63(W) x 40(H) mm
Weight : Approx. 218 gms